2. Re-assembly
a. Replace coupling and set screw on new motor shaft, mount motor on the adaptor assembly and replace set
screw on gear box shaft.
b. Re-install complete unit, reconnect electrical leads to micro-switch and capacitor. Reconnect ground wire.
c. Plug unit into wall outlet and test by manually pressing magnet switch.
NOTE
Always check the gear box grommets (2275-0208) whenever you have the upper
housing off. If they are worn or damaged, remove the old grommet and slip on
a new one.
d. Use sealant (Loctite No. 290) around black nylon bezels to insure that housings are sealed. Wipe off sur-
plus sealant.